Abstract
In page 6 of our Bio-protocol paper https://bio-protocol.org/e3229, we notice some mistakes and the correction details are listed below: Step E3: 80 should be 42.4 Step F is added: On-beads ligation for bridge adapter Set the reaction in a 1.5 ml tube in a rotator and ligate overnight at RT Step G1 is added: Add 80 µl 2x B&W buffer and 160 µl 1x B&W buffer. Put the beads against the 1.5 ml tube magnet stand and remove the supernatant. Wash the beads using 400 µl 1x B&W buffer three times and 400 µl dH2O once. Resuspend the beads in 80 µl dH2O.
References
If you have any questions/comments about this protocol, you are highly recommended to post here. We will invite the authors of this protocol as well as some of its users to address your questions/comments. To make it easier for them to help you, you are encouraged to post your data including images for the troubleshooting.