I was wondering at what wavelength DPBA was excited. also, did you encounter autofluorescence in that specific channel?

protocol Protocol: A Protocol for Flavonols, Kaempferol and Quercetin, Staining in Plant Root Tips

If there was autofluorescence, what microscope settings were used to distinguish auto fluorescent signal from DPBA signal?


answer Answer
recommend recommend recommend recommend Recommend
follow follow follow follow Follow
share share Share
1 answer
Sort by: most helpful / most recent

Nguyen Hoai Nguyen Author Answered Nov 28, 2023

Biotechnology Ho Chi Minh City Open University

Hi Hana,

Based on my own experience, I did not really observe the fluorescent signals (or the signal was very low) when I used the attenuated flavanols mutants such as the Arabidopsis ttg1 line. Thus, it is better to include the controls in your experiments such as non-treated samples, etc.

Regarding the excitation and emission wavelengths,

I am sorry for the missing info here.

The excitation is 488 (Argon) (for Kaempferol) and 561 (Hene) (for quercetin).

Let me know if you have any more questions.

Best wishes,

Nguyen

1 helpful
0 unhelpful