2.3.4. Carr’s Index (CI) and Hausner Ratio (HR)

WZ Wei-Feng Zhu
LZ Lin Zhu
ZL Zhe Li
WW Wen-Ting Wu
YG Yong-Mei Guan
LC Li-Hua Chen
ZM Zhi-Xuan Mao
LM Liang-Shan Ming
request Request a Protocol
ask Ask a question
Favorite

The bulk density (ρb) and tapped density (ρt) were determined by a powder characteristics tester (BT-1000, Bettersize Instruments, Ltd., Shanghai, China). The measuring cylinder was exactly 100 mL. The tapped time was 6 min for each material. The CI and HR were calculated with the following equations:

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

0/150

tip Tips for asking effective questions

+ Description

Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.

post Post a Question
0 Q&A