Typical procedure of CV (redox potential) measurements

AL Albert Tianxiang Liu
YK Yuichiro Kunai
AC Anton L. Cottrill
AK Amir Kaplan
GZ Ge Zhang
HK Hyunah Kim
RM Rafid S. Mollah
YE Yannick L. Eatmon
MS Michael S. Strano
request Request a Protocol
ask Ask a question
Favorite

Redox potentials of ferrocene derivatives were measured using cyclic voltammetry (CV). The CH3CN solution was prepared with adding 50 mM of TBAP as an electrolyte, and then 1 mM of each ferrocene derivative was added to prepare the solution for the CV measurement. The measurement was scanned at 50 mV/s, using a glassy carbon electrode and Ag/AgCl electrode for working and reference electrode, respectively (see Supporting Information 8).