Intracellular ATP levels were measured using a firefly luciferase-based bioluminescence ATP Assay Kit (Beyotime Biotechnology). Cell suspensions prepared from 1 plate was diluted to an OD600 of 0.2 and centrifuged at 12,000 rpm for 5 min at 4 °C. The obtained cell pellets were used to prepare intracellular ATP solution according to the supplier’s instructions. Cells were mixed with lysis solution and boiled for 2 min to release ATP and to inactivate endogenous ATPase [35, 36]. Then, 20 μL ATP extraction and 100 μL ATP detection solutions were mixed to prepare the luminescent reaction solution.
Luminance (RLU) was recorded using Hidex plate Chameleon™ V. (Finland) and linearly related to the ATP concentration.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.