The cooking loss of the HCD noodles was determined as described by AACC Method 66–50 [20]. The raw noodle sample (Ws, about 25 g) was placed into 400 mL of boiling distilled water until the optimal cooking time (OCT) was reached. The boiled noodle was removed from the cooking water and drained for 3 min and weighed. The cooking water was cooled to room temperature and transferred in a 500-mL volumetric flask filled with distilled water, and then 100 mL of it was transferred to a 250-mL beaker. After that, the beaker was placed into an air oven to dry at 105 °C until a constant weight was reached. The residue was weighed and calculated as a percentage of the starting material (dry weight basis). In a separate test, the same amount of fresh noodles was weighted, cooked to OCT, and removed from the cooking water. The boiled noodle was then reweighted after absorbing the water on the surface with 5 layers of filter paper. The water absorption index was calculated as the ratio of cooked noodle weight over the dry sample weight.
The texture properties of the uncooked and cooked HCD noodles were determined using a TA-XT2i texture analyzer (Stable Micro Systems, London, UK). The P/35 probe was used to measure the apparent stickiness of uncooked HCD noodles. The hardness of cooked HCD noodles was measured according to the description of Wu et al. with some modifications [21]. Fresh wet noodles were cooked to the OCT before removed from the cooking water and the remaining moisture on the surface of the boiled noodles was quickly dried by using five layers of filter paper after draining with cold water. Testing was completed within 15 min. The tensile testing was performed with an A/SPR probe and one strand of noodle was located through slots and was wound round parallel friction roller two or three times. The distance between the two rollers was set at 50 mm and the maximum operation distance was 100 mm. The pretest and test speed were 2.0 mm/s, and the post-test speed was 10.0 mm/s. For the hardness test, three strands of noodles were arrayed on the platform with HDP/FPS probe, and the pretest, test, post-test speed were 2, 0.8, 0.8 mm/s, respectively. The trigger force was 5 g and the compressive strain was 75%. The pause between the first and second compression was 2 s. Each of the noodle samples was tested at least 7 times and an average was applied.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.
 Tips for asking effective questions
+ Description
Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.