Cell growth assays

ZT Zhibo Tan
PZ Peitao Zhou
ZZ Zhenru Zhu
YW Ying Wang
ZG Zeqin Guo
MS Mengying Shen
YX Yazhi Xiao
WS Weixi Shen
DW Dehua Wu
ask Ask a question
Favorite

Cell growth was assessed using a Cell Counting kit-8 (CCK-8) and 5-ethynyl-2-deoxyuridine (EdU) incorporation assays (27). For CCK-8 assay, the TE-1 and Eca-109 cells were seeded at 2×103 cells/well into 96-well plates. After being incubated for 24, 48, or 72 at 37°C, 10 µl CCK-8 solution (Dojindo Laboratories, Inc.) were added to each well. The optical density values at 450 nm were measured with an enzyme-linked immune detector to indicate cell viability. EdU incorporation assay was performed using the Cell-Light™ EdU Apollo® 643 In Vitro Imaging kit (Guangzhou RiboBio Co., Ltd.) following the manufacturer's instructions. The results were detected using a Zeiss photomicroscope (Carl Zeiss AG) and counting was performed based on at least 10 random visual fields.