2.2.2. Tensile Test

WT Wataru Takarada
KS Kenichi Sugimoto
HN Hajime Nakajima
HV Hendrikus A. Visser
GG Gert-Jan M. Gruter
TK Takeshi Kikutani
request Request a Protocol
ask Ask a question
Favorite

The stress–strain curve of the PEF fibers was measured using a tensile testing machine (SHIMADZU AG-I, Kyoto, Japan). The gauge length was 20 mm and the crosshead speed was set to 20 mm/min. Tensile modulus, tensile strength, and elongation at break were obtained by averaging the results of 10 trials of the tensile test of the samples.