Tensile strength of the film and percentage elongation break test

MC Melbha Starlin CHELLATHURAI
VL Vivien WangTing LING
VP Vijayarajkumar PALANIRAJAN
request Request a Protocol
ask Ask a question
Favorite

Three pieces of film strips (4 cm x 2 cm) from each formulation were cut evenly, and the tensile strength and percentage elongation at break were evaluated using a tensiometer. The tensiometer consists of two load cell grips, a lower fixed one and an upper movable one. A film strip was fixed between these cell grips, and the force was gradually applied until the film broke.23 The tensile strength and percentage elongation at break were read directly from the dial reading.