Electrical characterization

NS Nellie Della Schiava
FP Francesco Pedroli
KT Kritsadi Thetpraphi
AF Annalisa Flocchini
ML Minh-Quyen Le
PL Patrick Lermusiaux
JC Jean-Fabien Capsal
PC Pierre-Jean Cottinet
request Request a Protocol
ask Ask a question
Favorite

Broadband dielectric spectroscopy (BDS) was performed using a Solartron 1260 impedance-analyzer (AMETEK Advanced Measurement Technology, England). Ambient temperature dielectric spectra are acquired under an alternative voltage of 1Vpeak-peak amplitude at a frequency range of 10−1–106 Hz.

The dielectric strength of the selected materials was determined by applying a DC voltage linear ramp at a slew rate of 500 V/s. For each polymeric film, 10 to 16 breakdown events were recorded to show the probability distribution of electrical failures.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

0/150

tip Tips for asking effective questions

+ Description

Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.

post Post a Question
0 Q&A