Lipids were extracted according to Bligh and Dyer [39], and the following internal standards were added: 20 pmol each of 1,2-dimyristoyl-sn-glycero-3-phosphoglycerol, 1,2-dilauroyl-sn-glycero-3-phosphoethanolamine, 1,2-dimyristoyl-sn-glycero-3-phosphoethanolamine, 1,2-di- heptadecanoyl-sn-glycero-3-phosphoethanolamine, 1,2-dimyristoyl-sn-glycero-3-phosphoserine, 1,2-dimyristoyl-sn-glycero-3-phosphate, 1,2-dipentadecanoyl-sn-glycero-3-phosphocholine, 1,2-di- heptadecanoyl-sn-glycero-3-phosphocholine, and 1,2-dinonadecanoyl-sn-glycero-phosphocholine.
The samples were re-dissolved in hexanes/2-propanol/water (42:56:2, v/v/v) and injected into a Thermo Scientific Dionex Ultimate 3000 high-performance liquid chromatograph equipped with an Ultimate HPG-3400SD standard binary pump and an Ultimate ACC-3000 autosampler column compartment (Waltham, MA, USA). Separation was carried using a FORTIS HILIC column (150 × 3 mm, 3 µm particle size) (Fortis Technologies, Neston, UK). The mobile phase consisted of a gradient of solvent A (hexanes/isopropanol 30:40, v/v) and solvent B (hexanes/isopropanol/20 mM ammonium acetate in water, 30:40:7, v/v/v). The gradient started at 75% A from 0 to 5 min, then decreased from 75% A to 40% A at 15 min, from 40% A to 5% A at 20 min, was held at 5% until 40 min, and then increased to 75% at 41 min. Then, the column was re-equilibrated holding 75% A for an additional 14-min period before the next sample injection [46]. The flow rate through the column was fixed at 0.4 mL/min. The liquid chromatography system was coupled online to an Sciex QTRAP 4500 Mass Spectrometer equipped with a Turbo V ion source and a TurbolonSpray probe for electrospray ionization (AB Sciex, Framingham, MA, USA). Source parameters were set as follows: ion spray voltage, -4500 V; curtain gas, 30 psi; nebulizer gas, 50 psi; desolvation gas, 60 psi; temperature, 425 °C. Phospholipid species were analyzed in scheduled multiple reaction monitoring mode with negative ionization, detecting in Q3 the m/z of either 303.2 or 331.2, corresponding to AA and AdA, respectively, as [M-H]−. Compound parameters were fixed as follows: declustering potential; −45 V (choline glycerophospholipids), −60 V (ethanolamine glycerophospholipids) −30 V (phosphatidylinositol), −50 V (phosphatidylserine), −60 V (phosphatidic acid), −50 V (phosphatidylglycerol); collision energy: −50 V (choline glycerophospholipids), −40 V (ethanolamine glycerophospholipids), −60 V (phosphatidylinositol), −50 V (phosphatidylserine), −45 V (phosphatidic acid), −45 V (phosphatidylglycerol); entrance potential, −10 V; and collision cell exit potential, −8 V. All glycerophospholipids were detected as [M-H]−, ions except choline glycerophospholipids, which were detected as [M + CH3COO]− ions. Quantification was carried out by integrating the chromatographic peaks of each species and comparing these with the peak area of the internal standard that corresponded to each class.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.