Intracellular calcium mobilization assays

SP Shubhi Pandey
XL Xaria X. Li
AS Ashish Srivastava
MB Mithu Baidya
PK Punita Kumari
HD Hemlata Dwivedi
MC Madhu Chaturvedi
EG Eshan Ghosh
TW Trent M. Woodruff
AS Arun K. Shukla
request Request a Protocol
ask Ask a question
Favorite

Ligand-induced intracellular calcium mobilization was assessed using Fluo-4 NW Calcium Assay kit (Thermo Fisher Scientific) following the manufacturer's instructions. Briefly, HMDMs were seeded (50,000/well) in black clear-bottom 96-well TC plates (Corning) for 24 h before the assay. The cells were first stained with the Fluo-4 dye in assay buffer (1× HBSS, 20 mm HEPES) for 45 min (37 °C, 5% CO2). Respective ligands were prepared in assay buffer containing 0.5% BSA. On a Flexstation 3 platform, the fluorescence (excitation/emission, 494/516 nm) was continually monitored for a total of 100 s with ligand addition performed at 16 s.