Each animal (n = 4 per group) received a 1.5 µl bilateral injection of 100 mM MnCl2. T1-weighted MEMRI was done immediately before and then 8 hrs post injection with a fast spin echo imaging sequence as described35. Briefly, slices were oriented orthogonal to the pre-chiasmatic ON. Other imaging parameters include: TR/TE = 600/8 ms, echo train length = 8, number of slices = 8, and slice thickness = 1 mm. A saline phantom was placed next to the rodent head for normalization. Signal intensity values, from IOP-injured and uninjured animals, before (pre-MEMRI) and 8 hrs after (post-MEMRI) MnCl2 injections were calculated as percentage differences between the right and left signal intensities and compared between pre- and post-MEMRI to determine the percent decrease in intensity in the ON, LGN, and SC.