MRI protocol

MS Mengfan Song
JL Jing Lin
FS Fuzhen Song
DW Dan Wu
ZQ Zhaoxia Qian
request Request a Protocol
ask Ask a question
Favorite

All scans were performed using a 1.5-T MR scanner (Aera, SIEMENS, Erlangen, Germany) with the patient in the supine position. The following sequences were used to acquire images, from which features were extracted for the radiomics model: axial T2-weighted imaging (T2WI) (repetition time/echo time = 4500 ms/80 ms, slice thickness = 6 mm, gap = 1 mm, field of view (FOV) = 320 * 240, flip angle = 160°, number of excitation = 2, with fat saturation), and axial diffusion-weighted imaging (DWI) (repetition time/echo time = 5200 ms/80 ms, field of view = 250 * 200, slice thickness = 6 mm, gap = 1 mm, flip angle = 90°, number of excitation = 6, b-value = 0, 800). The apparent diffusion coefficient (ADC) value was derived according to the following equation:

where S(b) and S(b0) represent the signal intensity of a certain voxel in the presence and absence of diffusion sensitization, respectively.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

0/150

tip Tips for asking effective questions

+ Description

Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.

post Post a Question
0 Q&A