2.8. Mechanical Properties Analysis of the Hydrogel

ZW Zhidan Wang
JW Jie Wu
XS Xiaoyu Shi
FS Fei Song
WG Wenli Gao
SL Shouxin Liu
ask Ask a question
Favorite

The mechanical properties of the gel were measured by DMA Q800 dynamic viscoelastic spectrometer. Five newly prepared double cross-linked gels, chemical gels, and physical gels were used to intercept disc-shaped gel samples with a puncher. DMA Q800 dynamic viscoelastic spectrometer was used to test the storage modulus of the hydrogel in a static compression multi-frequency strain mode, and the mechanical strength was described by comparing the storage modulus of the gel.