A controlled-stress HAAKE rheometer (Thermo Fisher, Waltham, MA, USA) equipped with a concentric cylinder (CC 25 Standard) was employed to characterize the flow behavior of fresh emulsions at 19 °C. Steady shear viscosity measurement of emulsions was performed at a shear rate ranging from 25 to 200 s−1. Measurements were run 3 times on fresh emulsions.