Apoptosis analysis using flow cytometry

QH Quanfu Huang
QW Qiuguo Wang
DL Dong Li
XW Xiao Wei
YJ Yijuan Jia
ZZ Zheng Zhang
BA Bo Ai
XC Xiaonian Cao
TG Tao Guo
YL Yongde Liao
ask Ask a question
Favorite

An Annexin V-FITC apoptosis kit (BD Biosciences, NJ, USA) was used to determine the number of apoptotic cells according to the manufacturer’s instructions. Different cell groups were harvested with 0.25% trypsin and washed with PBS. After centrifugation, the cells were re-suspended in 100 μl buffer and then stained with Annexin V (3 μl) and propidium iodide (PI; 5 μl), and the mixture was incubated in the dark at 4 °C for 15 min. The cells were sorted using a FACS Calibur flow cytometer (BD Biosciences, USA), during the assay 10,000 cells per sample were collect and count. The result were analyzed using Cell Quest software (BD Biosciences, USA). The experiments were repeated three times.