2.3. Echocardiography

AK Aureliusz Kolonko
MB Magdalena Bartmańska
NS Natalia Słabiak-Błaż
PK Piotr Kuczera
AK Agata Kujawa-Szewieczek
RF Rafał Ficek
AO Aleksander J. Owczarek
JC Jerzy Chudek
AW Andrzej Więcek
request Request a Protocol
ask Ask a question
Favorite

Echocardiographic studies were performed by 1 experienced investigator, using the Toshiba Xario 100 Diagnostic Ultrasound System (Toshiba, Toshiba Medical System Corporation, Tochigi 324-8550, Japan). M-mode and 2-dimensional measurements were performed as per recommendations of the American Society of Echocardiography. These measurements included left ventricular end-diastolic and end-systolic diameters, intraventricular septum, and posterior wall end-diastolic thickness. Left ventricular mass (LVM) was calculated according to Devereux formula.[17] LVM was indexed for BSA.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

0/150

tip Tips for asking effective questions

+ Description

Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.

post Post a Question
0 Q&A