Population-doubling level (PDL) calculation

SP Stoyan Petkov
TK Tobias Kahland
OS Orr Shomroni
TL Thomas Lingner
GS Gabriela Salinas
SF Sigrid Fuchs
KD Katharina Debowski
RB Rüdiger Behr
request Request a Protocol
ask Ask a question
Favorite

For determining PDL, the fibroblasts were passaged in 10 cm culture dishes (Thermo) with TrypLE at density of 2,5x105 cells /dish. When reaching confluency, cells were harvested and counted before being seeded again at 2,5x105 cells /dish for the next passage. Outgoing from consecutive counts, the PDL was calculated as follows: PDL(n/n-1) = log (Nf/N0)/log 2, where n = passage number, Nf = final number of cells, N0 = number of cells seeded at passage [38].