Measurement of blood pressure in mice

YH Yen-Chun Ho
MW Meng-Ling Wu
CS Chen-Hsuan Su
CC Chung-Huang Chen
HH Hua-Hui Ho
GL Guan-Lin Lee
WL Wei-Shiang Lin
WL Wen-Yu Lin
YH Yu-Juei Hsu
CK Cheng-Chin Kuo
KW Kenneth K. Wu
SY Shaw-Fang Yet
request Request a Protocol
ask Ask a question
Favorite

C57BL/6 wild-type mice (National Laboratory Animal Center, Taiwan) were used for experiments. A noninvasive tail-cuff method was used to measure systolic blood pressure (SBP) using a non-preheating MK-2000ST system (Muromachi Kikai Corp.). Conscious mice (~12-week-old male mice) were placed in special mouse holders and acclimated to the device for 10 min before measurement. A minimum of 3 serial measurements was made and the average value calculated. The SBP of each mouse was measured at baseline before IP injection of vehicle (PBS) or 5-MTP (Sigma, M4001) (100 mg/kg, 3 times a week9) and at different time points following initial injection. 5-MTP was dissolved in 0.05 N HCl (made in PBS) first, pH adjusted to 7.4 by NaOH, and then a stock solution of 6.5 mg/mL was prepared with PBS.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

post Post a Question
0 Q&A