High pH reversed-phase fractions were further fractionated using an Ultimate 3000 nano high performance LC system in line with an Orbitrap Fusion Tribrid mass spectrometer (Thermo Scientific). Peptides in 1% (vol/vol) formic acid were injected onto an Acclaim PepMap C18 nano-trap column (Thermo Scientific). After washing with 0.5% (vol/vol) acetonitrile, 0.1% (vol/vol) formic acid peptides were resolved on a 250-mm × 75-μm Acclaim PepMap C18 reversed-phase analytical column (Thermo Scientific) over a 150-minute organic gradient, using 7 gradient segments (1%-6% solvent B over 1 minute, 6%-15% B over 58 minutes, 15%-32% B over 58 minutes, 32%-40% B over 5 minutes, 40%-90% B for 1 minute, held at 90% B for 6 minutes, and then reduced to 1% B for 1 minute) with a flow rate of 300 nL per minute. Solvent A was 0.1% formic acid, and solvent B was aqueous 80% acetonitrile in 0.1% formic acid. Peptides were ionized by nanoelectrospray ionization at 2.0 kV using a stainless-steel emitter with an internal diameter of 30 μm (Thermo Scientific) and a capillary temperature of 275°C.
All spectra were acquired using an Orbitrap Fusion Tribrid mass spectrometer controlled by Xcalibur 2.0 software (Thermo Scientific) and operated in data-dependent acquisition mode using a synchronous precursor selection–MS3 workflow. Fourier transform mass analyzers (FTMS)1 spectra were collected at a resolution of 120 000, with an automatic gain control (AGC) target of 200 000 and a maximum injection time of 50 milliseconds. Precursors were filtered with an intensity threshold of 5000, according to charge state (to include charge states 2-7) and with monoisotopic precursor selection. Previously interrogated precursors were excluded using a dynamic window (60 seconds ± 10 ppm). The MS2 precursors were isolated with a quadrupole mass filter set to a width of 1.2 m/z. Ion-trap tandem mass spectrometry (ITMS2) spectra were collected with an AGC target of 10 000, the maximum injection time of 70 milliseconds, and collision-induced dissociation collision energy of 35%.
For FTMS3 analysis, the Orbitrap was operated at 50 000 resolution with an AGC target of 50 000 and a maximum injection time of 105 milliseconds. Precursors were fragmented by high-energy collision dissociation at a normalized collision energy of 60% to ensure maximal TMT reporter ion yield. Synchronous precursor selection was enabled to include up to 5 MS2 fragment ions in the FTMS3 scan.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.