The lenticules were placed in glycerol (Invitrogen) for 2 hours to reduce non-specific tissue swelling prior to optical evaluations21. The spectral transmittance of lenticules was determined using INFINITE 200 UV-Vis spectrophotometer (Tecan) with light wavelength ranged from 380 to 780 nm. Lenticules were placed on polystyrene coverslips (Thermanox, Nunc, 13 mm in diameter, 0.2 mm thick) and inserted into the spectrophotometer chamber for transmittance measurement. Data were collected at 10 nm wavelength increments. The transmittance coefficient (Ct) was calculated as Ct = It/I0, where (It was the transmitted light intensity and I0 was the incident light intensity)31. Experiments were triplicated and Ct of samples was normalized with the corresponding Ct of polystyrene coverslip and the mean percentage of transmittance to the control lenticule group was calculated.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.
Tips for asking effective questions
+ Description