Q-band CW EPR spectra were collected at 2 K on a spectrometer with a helium immersion Dewar as previously reported.35 Q-band pulsed Davies, Mims,36 and ReMims37 ENDOR spectra were collected at 2 K on a spectrometer with a helium immersion Dewar as previously reported.38 The intensity of the ENDOR response for the Mims sequence, [π/2-τ-π/2-T(rf)-π/2-τ-detect],36 follows the response function, I(A) ~ 1 − cos(2πAτ),36,27 and as a result, the signals at Aτ = n, n = 0, 1, …, are suppressed (“blind spots”).36 The Doan/ReMims sequence, [π/2-τ1-π/2-T(rf)-π/2-τ2-π-(τ1+τ2)-detect], allows use of a short preparation interval τ1 and study of a wider range of hyperfine values without “blind spot” distortions.37 The simulations of 2D field-frequency plots of ENDOR spectra collected across the EPR envelopes of E0 and hi-CO, presented below, were carried out with lab-written programs as described.39–41 Details of the analysis required to derive 13C-carbide hyperfine tensors are presented in the Supporting Information (SI).
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.
 Tips for asking effective questions
+ Description
Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.