The SVR methodology ("Neuroimaging and reconstruction") may not be readily available in clinical environments, and 2D measurements will often be performed on non-reconstructed images. To ensure reliable use of the calculator using 2D measurements performed prior and after SVR reconstruction, we have performed statistical agreement analysis between 2D measurements performed on T2-weighted ssTSE (non-reconstructed images typically acquired in a clinical scan) and their corresponding reconstructed images. All 2D measurements were performed by the same rater. The analysis was performed in a sub-cohort of ten fetuses (GA 21.71, 22.86, 25.29, 26.14, 28.29, 29.57, 31.71, 32.71, 34, and 36 weeks). Cases were selected to span the gestational period studied and only included symmetrical non-rotated images.