2.4. Feed Emulsion Droplet Size Analysis

QP Qun Peng
ZM Ziyi Meng
ZL Ziyang Luo
HD Hanying Duan
HR Hosahalli S. Ramaswamy
CW Chao Wang
ask Ask a question
Favorite

The droplet size of the emulsions was determined using an LA-950 laser scattering particle analyzer (Horiba Co., Ltd., Kyoto, Japan). Distilled water was used as the dispersant. Approximately 50–500 µL of each emulsion was added to the instrument and the droplet size distribution was expressed as per the following Equation (1):

where D43 is the average emulsion size, zi is the number of droplets of diameter Di. Each sample was determined twice, and the average was taken.