2.3. Detection of hUCMSC Surface Markers

YH Yajing Huang
YW Yanming Wu
XC Xinwen Chang
YL Yan Li
KW Kai Wang
TD Tao Duan
request Request a Protocol
ask Ask a question
Favorite

After three passages, hUCMSCs were examined for surface marker expression. Cells were trypsinized and washed with and resuspend in PBS to a density of 1 × 106 cells/mL. A volume of 100 μL of this cell suspension was added to 1.5 mL Eppendorf tubes. Tube 1 was used as a negative control (with PBS), and the other tubes were incubated with isotype control-FITC, CD73-FITC, CD90-FITC, CD105-FITC, CD14-FITC, CD34-FITC, or CD45-FITC antibodies for 30 minutes. The cells were then analyzed using flow cytometry.