Suspended solids

MB Maialen Barret
LG Laure Gandois
FT Frederic Thalasso
KC Karla Martinez Cruz
AJ Armando Sepulveda Jauregui
CL Céline Lavergne
RT Roman Teisserenc
PA Polette Aguilar
ON Oscar Gerardo Nieto
CE Claudia Etchebehere
BD Bruna Martins Dellagnezze
PW Patricia Bovio Winkler
GF Gilberto J. Fochesatto
NT Nikita Tananaev
MS Mette M. Svenning
CS Christophe Seppey
AT Alexander Tveit
RC Rolando Chamy
ME María Soledad Astorga España
AM Andrés Mansilla
AP Anton Van de Putte
MS Maxime Sweetlove
AM Alison E. Murray
LC Léa Cabrol
ask Ask a question
Favorite

Lake and hollow water samples (20 mL to 3 L, until clogging) were filtered on pre-weighted combusted GF/F grade glass microfiber filters (0.7 µm pore size, Whatman). The filters were dried overnight at 105 °C to calculate the total suspended solids (TSS). The filters were then incinerated at 550 °C for 2 hrs to determine the concentration of particulate organic matter (POM).

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

post Post a Question
0 Q&A