Human tumor-infiltrating lymphocyte flow cytometry

DP Dana Piovesan
JT Joanne B.L. Tan
AB Annette Becker
JB Jesus Banuelos
NN Nell Narasappa
DD Daniel DiRenzo
KZ Kristen Zhang
AC Ada Chen
EG Elaine Ginn
AU Akshata R. Udyavar
FY Fangfang Yin
SP Susan L. Paprcka
BP Bhamini Purandare
TP Timothy W. Park
NK Nikki Kimura
JK Jaroslaw Kalisiak
SY Stephen W. Young
JP Jay P. Powers
US Uli Schindler
KS Kelsey E. Sivick
MW Matthew J. Walters
ask Ask a question
Favorite

Dissociated tumor biopsies were obtained from Conversant Bio with informed written consent and according to Institutional Review Board (IRB)-approved guidelines in accordance with the Declaration of Helsinki. Subject information is detailed in Supplementary Table S2. Tumor samples were thawed and washed with PBS, blocked with Human Fc Block (BD Biosciences) before staining with fluorophore-conjugated antibodies for 30 minutes at 4°C. Cells were washed and resuspended in PBS for flow cytometric analysis.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

post Post a Question
0 Q&A