Mechanical Testing

CM Cory N. Meixner
MA Mohammad W. Aref
AG Aryaman Gupta
EM Erin M.B. McNerny
DB Drew Brown
JW Joseph M. Wallace
MA Matthew R. Allen
request Request a Protocol
ask Ask a question
Favorite

If you would like to request that the author provide a more detailed, step-by-step version of this protocol or you just have a question about the procedure, use the buttons above to request the protocol or ask the question.

Got it!

Whole bone mechanical properties were assessed in four-point bending as previously described [21] and in accordance with recommendations [26]. The anterior surface of each femur was placed on two lower supports with a span length of 9 mm and an upper span length of 3 mm. Specimens were loaded to failure at a rate of 2 mm/min, producing a force-displacement curve for each sample. Using a custom MATLAB program [24], structural and apparent material properties were determined. Apparent material properties were derived using standard beam-bending equations for four-point bending and geometric data from microCT analyses.

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

0/150

tip Tips for asking effective questions


+ Description

Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.

post Post a Question
0 Q&A