Quantification of Mitochondrial Acetyl-CoA Levels

CX Cen Xie
CJ Changtao Jiang
JS Jingmin Shi
XG Xiaoxia Gao
DS Dongxue Sun
LS Lulu Sun
TW Ting Wang
ST Shogo Takahashi
MA Mallappa Anitha
KK Kristopher W. Krausz
AP Andrew D. Patterson
FG Frank J. Gonzalez
ask Ask a question
Favorite

Liver mitochondria were prepared using a mitochondria isolation kit (Sigma-Aldrich). Acetyl-CoA levels in mitochondria were then determined using a PicoProbe acetyl-CoA assay kit (Abcam).