2.7.4. Accuracy and precision

SL Shuang Li
NY Na Yu
YT Yaoxin Tang
CL Chunshuang Liu
YZ Ying Zhang
XC Xiaojie Chen
HW Hao Wu
XL Xiubo Li
YL Yiming Liu
ask Ask a question
Favorite

Drawing upon the recovery rate and variability coefficient garnered from milk spiking, the accuracy and precision were evaluated. Four concentrations (0.2, 10, 20 and 40 ng/g) of blank milk were spiked to determine recovery rates. Analyzing six replicates of QC concentrations within the same day and evaluating five measurements of QC concentrations over five consecutive days assessed the accuracy and precision of the UPLC-MS/MS method.