3.4. UV-Vis Absorption Spectra

RR Ramón Rial
MG Michael González-Durruthy
MS Manuel Somoza
ZL Zhen Liu
JR Juan M. Ruso
request Request a Protocol
ask Ask a question
Favorite

UV-vis absorption spectra were recorded using a Cary 100 Bio UV-Vis Spectrophotometer. The spectral range studied was 240–400 nm. Lysozyme concentration was maintained constant at 0.02 mM and increasing concentrations of BTS from 0 mM to 0.01 mM were added to study how the different ratios affected the spectral results.