UV-vis absorption spectra were recorded using a Cary 100 Bio UV-Vis Spectrophotometer. The spectral range studied was 240–400 nm. Lysozyme concentration was maintained constant at 0.02 mM and increasing concentrations of BTS from 0 mM to 0.01 mM were added to study how the different ratios affected the spectral results.
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.