Synchrony between cells

SD Stéphane Deny
UF Ulisse Ferrari
EM Emilie Macé
PY Pierre Yger
RC Romain Caplette
SP Serge Picaud
GT Gašper Tkačik
OM Olivier Marre
request Request a Protocol
ask Ask a question
Favorite

To quantify the synchrony between cells, we displayed a 10-s bar movie to the retina, repeated 54 times. A maximum of 25 cells of the same type recorded simultaneously were subdivided in two groups, the distant cells, that were more than 200 μm away from the central bar position, and the central cells, that were less than 200 μm away from the central bar position. For all cells we computed the PSTH with a time bin of 20 ms. We computed the Pearson coefficient between all pairs of PSTHs of distant cells, and all pairs of PSTHs of central cells, respectively. We grouped the pairs based on the distance between their receptive field centers along the bar motion axis.