Measurement of the plasma digoxin levels

HS Huairui Shi
XM Xiaobo Mao
YZ Yucheng Zhong
YL Yuzhou Liu
XZ Xiaoqi Zhao
KY Kunwu Yu
RZ Ruirui Zhu
YW Yuzhen Wei
JZ Jianghao Zhu
HS Haitao Sun
YM Yi Mao
QZ Qiutang Zeng
ask Ask a question
Favorite

Twenty‐four hours after the final injection, blood was collected from the retro‐orbital vein, mixed and drawn into a capillary tube. Plasma was separated from the blood samples via low‐speed centrifugation (3000× g for 10 min at 4°C), collected and frozen at −80°C until analysis. The plasma digoxin levels were measured using a commercially available kit (Monobind Inc. Lake Forest, CA 92630, USA) according to the manufacturer's instructions.