发布: 2027年01月05日第17卷第1期 DOI: 10.21769/BioProtoc.5916 浏览次数: 12
评审: Harsimranjit SekhonAnonymous reviewer(s)
Abstract
Luciferase Activity Modulated by Phosphorylation (LAMP) is a genetically encoded bioluminescent biosensor platform that converts reversible protein phosphorylation into changes in NanoLuc luciferase activity. LAMP builds on NanoLuc Binary Technology (NanoBiT), in which low-affinity LgBiT and SmBiT fragments complement when brought into proximity by interacting proteins. In PKA LAMP, SmBiT is engineered with protein kinase A (PKA) phosphorylation sites and a protein phosphatase 2A (PP2A) recognition motif to generate PKABiT/pBiT. Phosphorylation inhibits LgBiT-pBiT complementation and decreases luminescence, whereas dephosphorylation restores complementation and increases luminescence. Here, we provide 96-well plate-reader protocols for implementing LAMP and its underlying NanoBiT complementation strategy in living cells. We describe empirical optimization of NanoBiT protein–protein interaction assays by comparing alternative N- and C-terminal reporter orientations. In contrast to NanoBiT interaction measurements, LAMP provides a robust kinetic readout in which stimulus-induced luminescence changes are normalized to each well’s own pre-treatment baseline. The modular cis and trans configurations established for LAMP provide a framework for coupling phosphorylation-sensitive complementation to protein interactions and signaling complexes. Together, these protocols provide sensitive, scalable approaches for measuring dynamic protein phosphorylation and protein interactions in living cells.
Key features
• LAMP adapts NanoBiT complementation to convert reversible protein phosphorylation into reciprocal changes in NanoLuc luminescence in living cells.
• PKA LAMP provides a kinetic, plate-reader-compatible readout of kinase/phosphatase signaling in which stimulus-induced luminescence changes are normalized to each well’s own pre-treatment baseline.
• Modular LAMP supports cis and trans configurations; PKA-binding and binding-deficient sensors assess PKA activity and A-kinase anchoring protein (AKAP)-mediated anchoring in living cells.
• The NanoBiT workflow compares N- and C-terminal reporter orientations and optionally normalizes protein–protein interaction (PPI) complementation to a HiBiT-defined maximal LgBiT response.
Keywords: A-kinase anchoring proteinsGraphical overview
NanoBiT complementation assay: NanoLuc luciferase is split into a small peptide (SmBiT) and a larger fragment (LgBiT), both being fused to two proteins of interest (POIs). Interaction of the fusion partners brings SmBiT and LgBiT into proximity and reconstitutes NanoLuc activity, producing luminescence as a readout of protein–protein interaction. Reporter orientation can strongly affect complementation and should therefore be optimized for each protein pair. LAMP assay: LAMP makes NanoBiT complementation sensitive to reversible phosphorylation. In the published PKA LAMP sensor, SmBiT is engineered with PKA phosphorylation sites and a protein phosphatase 2A (PP2A)/B56 recognition motif to generate PKABiT/pBiT. The cis sensor used in this protocol contains LgBiT and PKABiT on the same A-kinase anchoring protein (AKAP)-based polypeptide. Under basal conditions, complementation produces bright luminescence. Cyclic adenosine monophosphate (cAMP)-dependent activation of PKA phosphorylates PKABiT, inhibits complementation, and decreases luminescence; dephosphorylation has the opposite effect. LAMP can also be configured in trans, with LgBiT and pBiT attached to separate interacting proteins [1].
Background
Reversible protein phosphorylation is a ubiquitous regulatory mechanism controlled by the opposing activities of protein kinases and phosphatases. Genetically encoded kinase activity reporters permit real-time measurements of signaling in intact cells, but most established reporters rely on fluorescence and phosphorylation-dependent binding to phospho-amino-acid recognition domains. Many widely used kinase sensors incorporate forkhead-associated (FHA) domains, which preferentially bind phospho-Thr, whereas many Ser/Thr kinases, including protein kinase A (PKA), preferentially phosphorylate Ser [2–5]. Bioluminescent reporters offer a complementary approach with high sensitivity, low background, and no requirement for excitation light. NanoLuc luciferase is particularly well suited to this purpose because of its small size, high light output, and stability [6].
NanoLuc Binary Technology (NanoBiT) was developed to monitor protein–protein interactions (PPIs) in living cells [7]. NanoLuc is divided into LgBiT and the small, low-affinity SmBiT peptide. When these fragments are fused to interacting proteins, proximity promotes complementation and restores luciferase activity. Because SmBiT and LgBiT have low intrinsic affinity, complementation primarily reflects association of the fusion partners rather than reporter-driven binding. NanoBiT has been used in our studies of PKA and protein phosphatase 2A (PP2A) signaling complexes [8–10]. However, the geometry of the fusion proteins can strongly influence complementation, making empirical testing of N- versus C-terminal reporter placement and appropriate expression controls important for assay development.
We recently adapted NanoBiT to develop Luciferase Activity Modulated by Phosphorylation (LAMP), a bioluminescent biosensor platform for monitoring reversible protein phosphorylation in living cells [1]. Rather than using SmBiT solely as a passive proximity reporter, LAMP engineers the small NanoBiT component so that phosphorylation regulates its interaction with LgBiT. In the published PKA LAMP sensor, two PKA phosphorylation sites and a PP2A/B56 recognition motif were incorporated into SmBiT to generate PKABiT/pBiT. Phosphorylation inhibits LgBiT-pBiT complementation, likely through electrostatic and/or steric effects of the phosphate groups, whereas dephosphorylation restores complementation. This design produced an approximately sevenfold decrease in luminescence after PKA activation and an approximately sevenfold increase during dephosphorylation of a regeneratively phosphorylated sensor [1].
LAMP extends NanoLuc complementation from a measure of protein proximity to a reporter of enzymatic signaling. Replacing Thr with Ser in early PKA LAMP sensors substantially increased dynamic range, consistent with the Ser preference of PKA and many other Ser/Thr kinases [1,4,5]. The core LAMP sensor is small and modular: LgBiT and pBiT can be expressed in cis on the same polypeptide or in trans on separate interacting proteins [1]. For example, trans PKA LAMP demonstrated that PKA regulatory subunits RIα and RIβ form functional heterodimers in living cells, with activities indistinguishable from RIα and RIβ homodimers [1]. The published LAMP design can be adapted by modifying phosphorylation and dephosphorylation determinants and complements fluorescence-based biosensors.
The current protocol first describes empirical optimization of NanoBiT complementation for PPI measurements. Alternative placements of SmBiT and LgBiT at the N- or C-termini of interacting proteins can be compared in a 96-well plate-reader format. An optional feature is normalization of the NanoBiT PPI signal to maximal LgBiT complementation. After measuring SmBiT/LgBiT complementation, excess cell-permeable HiBiT peptide is added. Because HiBiT binds LgBiT with high affinity and outcompetes SmBiT, the resulting luminescence approximates a maximal response for the available LgBiT-tagged POI. Expressing the basal NanoBiT signal relative to this HiBiT-defined maximum provides a semi-quantitative means of accounting for differences in abundance and availability of the LgBiT fusion between conditions and for cell-density differences among technical replicates. A similar HiBiT-based normalization strategy has been described for NanoBiT measurements of RAS GTPase protein interactions [11]. The optimal NanoBiT orientation remains protein-pair dependent, so relevant configurations should be tested empirically rather than assuming that one fusion geometry will generalize. As an example, we compare the interaction of liprin-α1 with PP2A regulatory subunit B56δ, previously studied by coimmunoprecipitation [12], using a selected subset of reporter orientations (Figure 1). In this example, C-terminal SmBiT-tagged liprin-α1 paired with C-terminal LgBiT-tagged B56δ yields the highest light output. A liprin-α1 mutant that cannot interact with B56δ [12] serves as a negative control.
We then describe a 96-well plate-reader implementation of PKA LAMP. Unlike a NanoBiT PPI assay, LAMP does not depend on optimizing absolute complementation intensity because its principal output is the kinetic change in luminescence relative to each well’s own pre-treatment baseline. The protocol uses a published A-kinase anchoring protein LAMP sensor [1], which places LgBiT and PKABiT in cis on a scaffold based on small membrane AKAP (smAKAP), which selectively binds RI PKA regulatory subunits [13]. A nuclear exclusion sequence (NES) replaces smAKAP’s N-terminal plasma membrane-targeting sequence and confers cytosolic localization [1] (see Graphical overview). As an application, we compare signaling by wild-type (WT) PKA regulatory subunit RIβ and the R335W RIβ variant associated with Marbach-Schaaf neurodevelopmental syndrome [8,14]. Isoproterenol activates endogenous β-adrenergic receptor/cAMP signaling, and the resulting decrease in LAMP luminescence reports increased PKABiT phosphorylation. Comparison of the PKA-binding and binding-deficient (ΔPKA) sensors assesses the contribution of AKAP-mediated anchoring to the response (Figure 2).


Materials and reagents
Cell line
Potentially any cell line can be used for the NanoBiT complementation assay and the LAMP assay (see General note 2). We use HEK293 cells (ATCC, catalog number: CRL-1573) and Cos-1 cells (ATCC: CRL-1650) in this protocol.
Table 1. Plasmids used in this protocol
| Plasmid | Reference |
|---|---|
| pCMV PKA/RIβ-V5 sh5 WT | Pool et al. (2025) [8] |
| pCMV PKA/RIβ-V5 sh5 R335W | Pool et al. (2025) [8] |
| pEGFP-N1 2NES-AKAP-FLAG LgBiT-PKABiT27 (WT) | Kong and Strack (2025) [1] |
| pEGFP-N1 2NES-AKAP-FLAG L65,70P LgBiT-PKABiT27 (ΔPKA) | Kong and Strack (2025) [1] |
| pCMV LipA1-FLAG-SmBiT (Lipα-Sm) | unpublished |
| pCMV LipA1-FLAG-SmBiT m1,4,8 (Lipα*-Sm) | unpublished |
| pCMV LipA1-FLAG-V5-LgBiT (Lipα-Lg) | unpublished |
| pCMV B56delta-FLAG-SmBiT (B56δ-Sm) | unpublished |
| pCMV SmBiT-B56delta (Sm-B56δ) | unpublished |
| pCMV B56delta-FLAG-V5-LgBiT (B56δ-Lg) | unpublished |
Reagents
1. Isoproterenol (Sigma-Aldrich, catalog number: I5627-5G)
2. Hank’s balanced salt solution (HBSS) (GIBCO, catalog number: 14175-095)
3. Opti-MEM (GIBCO, catalog number: 31985-070)
4. High-glucose DMEM (GIBCO, catalog number: 11965-092)
5. Fetal bovine serum (FBS) (GIBCO, catalog number: 26140079)
6. Collagen Type I (rat tail, 3.25 mg/mL) (GIBCO, catalog number: 354236)
7. Lipofectamine 2000 (Invitrogen, catalog number: 11668019)
8. 1 M HEPES (GIBCO, catalog number: 15630-080)
9. 100× GlutaMax (GIBCO, catalog number: 35050-061)
10. Fluorofurimazine (FFz) (DC Chemicals, catalog number: DC74576)
11. Collagen Type I rat tail (Corning, catalog number: 354236)
12. Custom-made cell-permeable HiBiT peptide (RRRRRRRRRGVSGWRLFKKIS) (GenScript Biotech)
Note: N-terminal arginine (R) residues are not needed when cells are lysed in Triton X-100-containing buffer, as in this protocol.
13. Triton X-100 (Fisher BioReagents, catalog number: BP151-500)
14. Tris base (Research Products International, catalog number: T60040)
15. Ethanol, 95% (Decon Laboratories, catalog number: 2801)
16. Ethanol, 100% (Decon Laboratories, catalog number: 2716)
Solutions
1. Collagen-coating solution (see Recipes)
2. Cos medium (see Recipes)
3. 1/10th Cos medium (see Recipes)
4. HiBiT peptide solution (see Recipes)
5. Fluorofurimazine stock (see Recipes)
Recipes
1. Collagen-coating solution
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| Collagen Type I (from rat tail) | 1:100 (32.5 μg/mL) | 0.5 mL |
| 30% ethanol | n/a | 49.5 mL |
2. Cos medium
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| DMEM | n/a | 500 mL |
| Heat-inactivated FBS | 10% | 55.6 mL |
| 100× GlutaMax | 1 mM | 5.56 mL |
| Total | n/a | 561.16 mL |
Heat-inactivate thawed FBS at 55 °C for 30 min. Heat-inactivated FBS can be stored at -20 °C and thawed in a water bath before Cos medium preparation. Filter-sterilize and warm the Cos medium in a water bath before use.
3. 1/10th Cos medium
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| DMEM | n/a | 4.445 mL |
| Cos medium | n/a | 0.49 mL |
| 1 M HEPES | 10 mM | 50 μL |
| 100× GlutaMax | 1 mM | 44 μL |
| Total | 5 mL |
4. HiBiT peptide solution
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| 1/10th Cos medium | n/a | 1.079 mL |
| 10% Triton | 1% | 120 μL |
| 20 mg/mL HiBiT peptide | 12 μg/mL | 0.72 μL |
| Total | 1.2 mL (10 μL/well) |
5. Fluorofurimazine stock
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| 100% ethanol | n/a | 1.0 mL |
| Fluorofurimazine powder | 25 mM | 10.81 mg |
Store at -20 to -80 °C in an opaque tube or wrapped in aluminum foil.
Laboratory supplies
1. 100 mm tissue culture dishes (e.g., Sarstedt, catalog number: 83.3902, or similar)
2. 5 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11D, or similar)
3. 10 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11E, or similar)
4. 25 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11, or similar)
5. 96-well plates, white, clear flat bottom, sterile (e.g., Corning, catalog number: 3610, or similar)
6. 15 mL conical tubes (e.g., Sarstedt, catalog number: 62.553.205, or similar)
7. 50 mL conical tubes (e.g., Sarstedt, catalog number: 62.547.100, or similar)
8. 500 mL filter unit with 0.2 μm PES membrane (e.g., Thermo Fisher, catalog number: 569-0020, or similar)
9. 1,000 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000063, or similar)
10. 200 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000055, or similar)
11. 10 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000020, or similar)
12. 12-channel repeat pipettor (e.g., Eppendorf, catalog number: 4861000791, or similar)
13. Hemocytometer (e.g., Hausser Scientific Bright-Line, catalog number: 3110, or similar)
14. Single-channel repeat pipettor (e.g., Eppendorf, catalog number: 4987000134, or similar)
Equipment
1. 96-well plate reader (e.g., TECAN SPARK, BioTek, Molecular Devices)
Software and datasets
1. GraphPad Prism (GraphPad Software) or similar program for statistical analysis
2. Microsoft Excel or similar program for data entry and analysis
Procedure
登录 / 注册后阅读全文
文章信息
稿件历史记录
提交日期: Oct 2, 2026
接收日期: Nov 16, 2026
在线发布日期: Nov 26, 2026
出版日期: Jan 5, 2027
版权信息
© 2027 The Author(s); This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).
如何引用
Readers should cite both the Bio-protocol article and the original research article where this protocol was used:
您对这篇实验方案有问题吗?
在此处发布您的问题,我们将邀请本文作者来回答。同时,我们会将您的问题发布到Bio-protocol Exchange,以便寻求社区成员的帮助。