(*contributed equally to this work) 发布: 2027年01月05日第17卷第1期 DOI: 10.21769/BioProtoc.5911 浏览次数: 16
评审: Elena A. OstrakhovitchSalah BoudjadiPriyanka Shandilya
Abstract
Early detection of primary and metastatic cancer has a profound influence on prognosis for all cancers. Currently, imaging CT/MRI and/or 18F-FDG-PET followed by tissue biopsy is the gold standard for detection in clinical practice, depending on the lesion site. Specificity and sensitivity of imaging modalities, depending on the type of cancer and its site, remain challenging. Here, we report on a developing technology, magnetic particle imaging (MPI), for the detection of primary tumors and metastases using a mouse model of breast cancer. Using this technique, we identified multiple metastatic lesions in mice bearing luciferase-expressing 4T1 breast tumors, which were not clearly defined by bioluminescence or microCT imaging. Post-processing of imaging data using an improved algorithm yielded higher-resolution images, enabling quantification of signal intensity of micrometastatic lesions throughout the mouse body.
Key features
• Commercial SynomagTM nanoparticles coated with poly(ethylene glycol) by the manufacturer were used to detect mammary tumors and metastases in a mouse model of breast cancer.
• Magnetic particle imaging, a new tracer imaging technique, was used for detecting cancer lesions.
• With improved processing algorithms, we were able to detect microscopic lesions that could not be seen with micro-computed tomography or bioluminescent imaging.
• MPI promises to provide another imaging modality for cancer.
Keywords: Magnetic particle imaging (MPI)Graphical overview
Iron oxide nanoparticles accumulating in the primary and metastatic tumor microenvironment enable their non-invasive detection by magnetic particle imaging
Background
Magnetic particle imaging (MPI) is a new tracer imaging technique that generates signals from magnetic materials (tracers) when exposed to an oscillating magnetic field [1]. Unlike computed tomography scans, which use X-rays, a sample scanned with MPI is not exposed to ionizing radiation, making it more suitable for living subjects. Superparamagnetic iron oxide (SPIO) nanoparticles are shown to be ideal tracers for generating quality MPI signals [2,3]. To create an image, the MPI scanner uses opposing magnets to generate a field-free region (FFR), which is then rastered over the sample [2]. The scanner then uses a low frequency/low amplitude alternating magnetic field to force the tracer’s magnetic moments within the FFR to oscillate and generate a potential that is proportional to the number of nanoparticles. Outside the FFR region, SPIOs are magnetically saturated and produce no signal. The receiver coil detects the voltage created by the SPIOs when their magnetic moments oscillate 180° from their current voxel due to the superimposed alternating magnetic field when the FFR is scanned across their location. This signal, picked up by the receiver coil, can then be reconstructed as an image using reconstruction algorithms like harmonic-space or x-space [2,4]. This method exhibits high sensitivity, enabling the quantitative detection of nanogram tracer quantities. It is also unaffected by air or other void volumes, making it suitable for imaging lung metastases; locations devoid of the nanoparticle tracer generate no signal, reducing or eliminating background noise. MPI also does not generate signal from tissue (which is weakly diamagnetic) and thus must be co-registered with computed tomography (CT) or magnetic resonance imaging (MRI).
Here, we describe methods to detect tumors and metastases as reported in our previous study [5]. Targeting, or directing, nanoparticles to tumors has historically presented a challenge. Our recent research has shown that SynomagTM nanoparticles, coated with poly(ethylene glycol), are taken up by inflammatory cells and tissues (e.g., macrophages, fibroblasts, and collagen) in the tumor microenvironment, thereby enabling tumor detection by MPI [5]. We recently showed that SynomagTM nanoparticles, which are not superparamagnetic, are instead aggregated multi-core ferrite nanoparticles, or nanoflowers with magnetic anisotropy that makes them suitable tracers for MPI [6].
More recently, we reported that antibody-conjugated nanoparticles also accumulate in tumors and other non-cancer sites of inflammation, apart from organs of the reticuloendothelial system (liver and spleen). These non-cancer sites can be distinguished from tumors because they have a uniform and bright signal, whereas cancer tumors show a distinct outer ring pattern that distinguishes them [7]. This unique pattern to distinguish cancer from non-cancer tissues was used to detect tumors. In all cases, cancer was confirmed with post-mortem histopathology.
Materials and reagents
Biological materials
1. BALB/c mice (8-week-old female BALB/c mice from Jackson Labs, stock no: 000651) with primary tumor and metastases
2. Breast cancer cells -4T1-luc (gift from Dr. Saraswati Sukumar, Johns Hopkins University); alternatively, cells can be purchased from American Type Culture Collection (ATCC) 4T1-Luc2, catalog number: CRL-2539-LUC2
Reagents
1. Hydroxyethyl starch- and poly(ethylene glycol)-coated iron oxide nanoparticles, Synomag®-PEG (SPEG) nanoparticles (Micromod Partikeltechnologie, catalog number: 105-124-102); store at 4 °C
Note: SPEG nanoparticles are composed of 50-nm aggregated multi-core ferrite nanoparticles or nanoflowers with iron oxide ferrite cores coated with hydroxyethyl starch as the shell material, resulting in a hydrodynamic diameter of 100 nm. This was then covalently bonded to polyethylene glycol (PEG 25000-OMe) [5,6].
2. VivoTrax nanoparticles (Magnetic Insight, catalog number: MIVT01-LOT00009); store at 4 °C
Note: VivoTrax is a preclinical superparamagnetic iron oxide nanoparticle with a magnetite iron core and dextran coating similar to Ferucarbotran/Resovist, a clinically approved liver MRI contrast agent. The core iron size of VivoTrax is 4.2 nm, and the hydrodynamic diameter is 62 nm [7]. In vitro MPI signal and resolution characteristics of SPEG and VivoTrax showed that SPEG is superior to VivoTrax [5].
3. Roswell Park Memorial Institute (RPMI 1640) medium (Thermo Fisher Scientific, catalog number: 11875093)
4. Fetal bovine serum (FBS) (MilliporeSigma, catalog number: TMS-013-B)
5. Trypsin EDTA 1×, 0.25% (Thermo Fisher Scientific, catalog number: 25200056)
6. PierceTM D-Luciferin, monosodium salt, 1 g (Thermo Fisher Scientific, catalog number: 88292)
7. Isoflurane (MWI Animal Health, catalog number: NDC 13985-528-40)
8. Phosphate-buffered saline (PBS) (Quality Biologicals, catalog number:114-058-101CS)
Laboratory supplies
1. BioLite cell culture-treated flasks (T75) (Thermo Fisher Scientific, catalog number: 130190)
2. Corning® Costar® Stripette® serological pipettes, individually paper/plastic wrapped, capacity 5 mL (MilliporeSigma, catalog number: CLS4487)
3. Tips LTS 20 μL filter 960/5 SR-L10F (Rainin, catalog number: 17005860)
4. NuncTM conical sterile polypropylene centrifuge tubes (racked) (Thermo Fisher Scientific, catalog number: 339651)
5. 5 mL tubes (Fisher Scientific, catalog number: 50-302-8556)
6. Exel, 1cc TB syringe w/ 25g × 5/8" Needle (Exelint International, catalog number: EXE26044)
7. BD PrecisionGlideTM needle, 30 G × 1/2 in. (Becton Dickinson, catalog number: 305106)
8. FisherbrandTM sterile alcohol prep pads (Fisher Scientific, catalog number: 22-363-750)
9. Small tubes, MicroAmp fast reaction tube with cap (Applied Biosystems, catalog number: 4358297)
10. Eye lube (GenTeal tears, Alcon Inc.)
11. Paper surgical tape, 3" × 10 yds (Thomas Scientific, catalog number: 1152J14)
12. Ice
13. Tube holders and racks
Equipment
1. Cell culture incubator ((Thermo Fisher Scientific, model: HeracellTM VIOS 160i CO2 Incubator)
2. Centrifuge (Eppendorf, model: 5424R)
3. Cell counter (Denovix, model: S-10696)
4. IVIS Imaging system (PerkinElmer IVIS In Vivo Imaging System, model: 124262)
5. Tailveiner® Restrainer for Mice (Braintree Scientific, model: TV-150)
6. Isoflurane vaporizer (Midmark, model: Matrx VIP 3000-91305418)
7. Small Animal Monitoring & Gating System (SA Instruments, model: 1025T-FOT)
8. MOMENTUM MPI scanner (Magnetic Insight)
9. IVIS Spectrum CT System (Perkin-Elmer)
Software and datasets
1. Living ImageTM (Revvity, USA)
2. MATLAB (The MathWorks, Inc., Natick, MA, USA); a recent MATLAB version with GPU computing support is required for the reconstruction code used in this protocol
3. Momentum scanner software (Magnetic Insight, Inc.), installed on the computer supplied with the Momentum MPI scanner
4. MagImage (Magnetic Insight, Inc.), 3D Slicer, or equivalent image analysis software may be used for visualization, image registration, segmentation, and quantitation
5. MATLAB code for model-based 2D and 3D field-free-line MPI reconstruction is publicly available at https://github.com/toby-sanders/MPI-FFL-reconstruction
6. Experimental data associated with the original study are publicly available through the Johns Hopkins Research Data Repository: https://doi.org/10.7281/T1QZ3N5L
Procedure
登录 / 注册后阅读全文
文章信息
稿件历史记录
提交日期: Sep 21, 2026
接收日期: Nov 15, 2026
在线发布日期: Nov 27, 2026
出版日期: Jan 5, 2027
版权信息
© 2027 The Author(s); This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).
如何引用
Korangath, P., Carlton, H., Sanders, T., Goodwill, P. W. and Ivkov, R. (2027). Detecting Metastases by Magnetic Particle Imaging Using Pegylated Synomag Nanoparticles in Murine Breast Cancer Models. Bio-protocol 17(1): e5911. DOI: 10.21769/BioProtoc.5911.
您对这篇实验方案有问题吗?
在此处发布您的问题,我们将邀请本文作者来回答。同时,我们会将您的问题发布到Bio-protocol Exchange,以便寻求社区成员的帮助。
Share
Bluesky
X
Copy link