Please leave your comments or questions
 
QIAprep® Spin Miniprep Kit
Authors: Eric Chang and Marielle Cavrois, updated date: , view: 7, Q&A: 0
Tag: Cloning

Procedure

QIAprep® Spin Miniprep Kit

 

Notes:

  • Grow clones STBL2  @  30˚C and STBL3 @ 37˚C

 

Materials and Reagents

  • The QIAprep Spin Miniprep Kit (cat. nos. 27104 and 27106) can be stored at room temperature (15–25˚C) for up to 12 months.

  • 12 ml Falcon tubes

 

Equipment

  • Centrifuge


Procedure

  1. Grow bacteria clone (~2.5 ml) overnight in LB with appropriate antibiotic

  2. Add LyseBlue reagent to Buffer P1 at a ratio of 1 to 1000. Add the provided RNase A solution to Buffer P1, mix, and store at 2–8˚C.

  3. Add ethanol (96–100%) to Buffer PE before use (see bottle label for

  4. volume).

  5. Transfer 2 ml of culture into a 2ml eppendorf tube

  6. Pellet the bacterial overnight culture by centrifugation at >5,000 rpm for 10 min at room temperature (15–25˚C).

  7. Pour the supernatant out and place Eppendorf tube in a rack

  8. Remove the left over LB media that drip down onto the pellet

  9. Resuspend pelleted bacterial cells in 250 μl Buffer P1

  10. Add 250 μl Buffer P2 and mix thoroughly by inverting the tube 4–6 times until the solution

  11. becomes blue. Do not allow the lysis reaction to proceed for more than 5 min.

  12. Add 350 μl Buffer N3 and mix immediately and thoroughly by inverting the tube4–6 times. If using LyseBlue reagent, the solution will turn colorless.

  13. Centrifuge for 10 min at 13,000 rpm (~17,900 xg) in a table-topmicrocentrifuge.

  14. Label the QIAprep spin column

  15. Apply the supernatant from step 5

  16. Centrifuge for 1 min at 13,000 rpm (~17,900 xg) in a table-top microcentrifuge. Empty the bottom tube

  17. Wash the QIAprep spin column by adding 0.5 ml Buffer PB.

  18. Centrifuge for 1 min at 13,000 rpm (~17,900 xg) in a table-top microcentrifuge. Empty the bottom tube

  19. Wash the QIAprep spin column by adding 0.75 ml Buffer PE.

  20. Centrifuge for 1 min at 13,000 rpm (~17,900 xg) in a table-top microcentrifuge. Empty the bottom tube

  21. Spin again for 1min

  22. Dry the column by waiting 5 min

  23. Transfer column to labelled Eppendorf tube

  24. Add 50 ul of water

  25. Centrifuge for 1 min at 13,000 rpm (~17,900 xg) in a table-top microcentrifuge. Empty the bottom tube

 

References

http://www.qiagen.com/knowledge-and-support/resource-center/resourcedownload.aspx?id=331740ca-077f-4ddd-9e5a-2083f98eebd5&lang=en

 


Comment
Please login to post your questions/comments. Your questions will be directed to the authors of the protocol. The authors will be requested to answer your questions at their earliest convenience. Once your questions are answered, you will be informed using the email address that you register with bio-protocol.
You are highly recommended to post your data including images for the troubleshooting.
You are highly recommended to post your data (images or even videos) for the troubleshooting. For uploading videos, you may need a Google account because Bio-protocol uses YouTube to host videos.