Plasma and medium concentrations of acyl-ghrelin and des-acyl ghrelin were measured by an acylated Ghrelin (mouse, rat) Express EIA Kit (A05117, SPI Bio, Montigny-le-Bretonneux, France) and an Unacylated Ghrelin (mouse, rat) Express EIA Kit (A05118, SPI Bio). Acyl-ghrelin and des-acyl ghrelin concentrations were determined according to the manufacturer’s protocol. For acyl-ghrelin ELISA, the intra-assay coefficient of variation = 5.7%, and the inter-assay coefficient of variation = 6.1%. For des-acyl ghrelin ELISA, the intra-assay coefficient of variation = 5.2%, and the inter-assay coefficient of variation = 5.5%. Absorbance data were collected by using a Bio-Rad iMark Microplate Reader spectrophotometer, using Microplate Manager 6 Software (Bio-Rad, Hercules, CA, USA). Total ghrelin was calculated by adding acyl-ghrelin and des-acyl ghrelin concentrations together.