Portal pressure measurements

AP Andrea Peloso
SL Stéphanie Lacotte
QG Quentin Gex
FS Florence Slits
BM Beat Moeckli
GO Graziano Oldani
MT Matthieu Tihy
AH Aurélie Hautefort
BK Brenda Kwak
LR Laura Rubbia-Brandt
CT Christian Toso
MA Matias A Avila
MA Matias A Avila
MA Matias A Avila
request Request a Protocol
ask Ask a question
Favorite

After 40 weeks of HFD, we measured portal pressure in sham-operated and shunted mice (n = 4 group CD; n = 10 group HFD; and n = 10 group HFD/shunt). After a midline laparotomy, the ileocolic vein was cannulated using 27G BD Valu-Set (BD, Belliver Industrial Estate, Plymouth, UK) and connected to a calibrated digital pressure analyser (Micro Pressure Transducer with Amplifier; Radnoti Monrovia, CA, US). Portal pressure was continuously monitored, and the average over 30 seconds was recorded. Upon sacrifice of the animal, the spleen and the liver were removed, weighed, and liver/spleen weight ratio was calculated.

Search protocols in the Bio-protocol database

Do you have any questions about this protocol?

Post your question to gather feedback from the community. We will also invite the authors of this article to respond.

post Post a Question