Hypoxia‐treated HUH7, SNU‐182 and HLF cells were collected. Total RNA was extracted from treated cells using TRIzol Reagent following the protocol from the manufacturer's instructions. The concentration and quality of total RNA were measured using NanoDrop microvolume spectrometer. The RNA samples with high quality were labelled and hybridized on Agilent Whole human genome chip (4 × 44 K). Differentially expressed mRNAs were extracted using R software (version 3.6.1) with Limma package.