Normalization of field intensity
This protocol is extracted from research article:
Optical pulling at macroscopic distances
Sci Adv, Mar 29, 2019; DOI: 10.1126/sciadv.aau7814

A number of incident beams were adopted in this study. For Eqs. 4 to 6, the intensity at the beam center was normalized to 1 mW μm−2. This normalization could not be applied to the m = 0 azimuthally polarized Bessel beam given in Eq. 3 because it had a dark center along the beam axis. Thus, we normalized the intensity maximum of the beam to 1 mW μm−2. We note that 1 mW μm−2 was a modest intensity, and we were more concerned about the direction of the force than its exact magnitude.

Note: The content above has been extracted from a research article, so it may not display correctly.



Q&A
Please log in to submit your questions online.
Your question will be posted on the Bio-101 website. We will send your questions to the authors of this protocol and Bio-protocol community members who are experienced with this method. you will be informed using the email address associated with your Bio-protocol account.