Four-terminal probe measurements were conducted with a probe pitch of 300 μm (NTT Advanced Technology). A constant current of 100 μA was applied at the ends of the probes. To change the measured voltage V into a sheet resistance Rsh, we used a standard calibration equation, Embedded Image. The scanning step of the x axis (y axis) corresponded to 300 μm (100 μm).

Note: The content above has been extracted from a research article, so it may not display correctly.



Q&A
Please log in to submit your questions online.
Your question will be posted on the Bio-101 website. We will send your questions to the authors of this protocol and Bio-protocol community members who are experienced with this method. you will be informed using the email address associated with your Bio-protocol account.



We use cookies on this site to enhance your user experience. By using our website, you are agreeing to allow the storage of cookies on your computer.